Technical Information

Below you will find some general information about the construction and fixing of our panels as well as a Sizing Diagram, a Panel Height Diagram, and an Emissions Chart. You can also download an Absorption Graph and Output Graph as Microsoft Excel files for customised use in your own projects.

Notice : To All Clients

All panels supplied by Solray in a primer coated condition require final painting in order to achieve listed ouputs.

Emissions are only valid for Solray panels either powder coated or painted by others on site; they are not valid for panels left primed without final painting.

If in any doubt about any conditions, contact head office or place your comments in the Contact Us section of this website.

Excel Charts

Absorption Graph
Absoption Graph.xls

Output Graph
Output Graph.xls

To download the graphs as an Excel file follow these instructions:

1. Click-and-hold (Win95/98 users right-click) on the appropriate link above.

2. From the menu that appears, choose 'Save Link As...', 'Save Target As...' or 'Download Link to Disk'.

3. Choose where you'd like to save the image. Click 'Save' (if asked to save as either 'text' or 'source', choose 'source').

 

Sizing & Fitting

The tables below can be used as a guide to help develop your design. If you require any detailed assistance, please contact the London office.

Sizing & Fitting Charts

 

Emissions Graphs

Emissions Graphs

GENERAL INFORMATION
This Chart is for use with plain horizontal surfaces looking up, i.e. Panels in Floors. For vertical plain surfaces deduct from the convection figure as follows:- Up to 300mm above FFL = Nil, 300 to 600mm = 10%, Above 600mm = 20%. For horizontal plain surfaces looking down, i.e. ceilings, deduct 50% from the convection figure. These figures are based on still air conditions. In certain circumstances, particularly in floor warming, the emission by convection may be increased by as much as 25% through air movement over the heated surface.

 

Solray Emissions Chart

All Panels outputs are tested in accordance with EN 14037

 

TEMPERATURE TOTAL WATTS PER SQUARE METRE
Mean water
or steam °C
Ambient °C FLOOR WALL (mm)
<300 <600 >600
CEILING
Panel/Perimeter/Strip
35 14
16
18
20
22
165
145
130
110
95

200 190 180
180 170 160
160 155 145
140 135 125
120 115 110

150
135
120
105
90
40 14
16
18
20
22
210
190
175
155
140
260 245 230
240 225 215
215 205 195
195 185 175
175 165 155
190
175
160
145
130
45 14
16
18
20
22
260
240
225
205
185
320 305 285
300 285 265
275 265 245
255 245 230
235 220 210
235
220
205
190
175
50 14
16
18
20
22
310
295
275
255
235
385 365 340
360 345 320
340 320 300
315 300 285
295 280 265
280
265
250
235
215
55 14
16
18
20
22
365
345
325
310
290
450 425 400
425 405 380
405 385 360
380 360 340
360 340 320
325
310
295
280
265
60 14
16
18
20
22
425
400
380
360
340
515 490 460
495 470 440
470 450 420
450 425 400
425 405 380
375
360
345
330
310
65 14
16
18
20
22
480
460
440
420
400
590 560 525
565 535 500
540 515 480
515 490 460
595 470 440
425
410
395
380
360
70 14
16
18
20
22
540
520
500
475
455
660 625 585
635 605 565
610 580 545
590 560 525
565 535 505
495
460
445
430
415
75 14
16
18
20
22
600
580
560
535
515
735 700 655
710 675 635
685 655 610
660 630 590
640 605 570
530
515
500
485
465
76.67 (170°F)

12.8 (55°F)
15.6 (60°F)
18.3 (65°F)
21.1 (70°F)

635
605
575
545
775 735 690
740 705 660
710 675 630
675 640 600
560
535
515
495
80 14
16
18
20
22
665
640
620
600
575
810 770 720
790 750 700
765 725 680
740 700 660
715 680 640
590
570
555
540
525
85 14
16
18
20
22
725
705
685
660
640
890 845 795
865 825 770
840 800 750
815 775 730
790 755 710
645
630
615
595
580
90 14
16
18
20
22
  975 925 865
950 900 845
925 875 825
900 855 800
875 830 780
705
690
675
655
640
95 14
16
18
20
22
  1155 1005 940
1030 980 920
1105 955 895
980 935 875
955 910 855
765
750
735
715
700
100 14
16
18
20
22
  1140 1085 1115
1115 1060 995
1090 1040 975
1065 1015 950
1040 990 930
830
815
795
780
765
105 14
16
18
20
22
  1230 1170 1095
1205 1145 1075
1180 1120 1050
1150 1095 1030
1130 1075 1010
895
880
860
845
830
110 14
16
18
20
22
  1320 1255 1175
1295 1230 1155
1270 1205 1135
1245 1185 1110
1215 1160 1090
960
945
930
910
895
115 14
16
18
20
22
  1415 1345 1260
1385 1320 1240
1360 1295 1215
1335 1270 1195
1310 1245 1170
1030
1115
1000
980
965
120 14
16
18
20
22
  1510 1435 1345
1480 1410 1325
1455 1385 1300
1430 1360 1280
1405 1335 1255
1100
1085
1070
1050
1035
125 14
16
18
20
22
  1605 1525 1430
1580 1500 1410
1550 1475 1385
1525 1450 1365
1500 1430 1340
1175
1160
1140
1125
1105
130 14
16
18
20
22
  1705 1620 1520
1675 1595 1500
1650 1570 1475
1625 1545 1455
1595 1520 1430
1250
1230
1215
1200
1180
135 14
16
18
20
22
  1805 1715 1615
1780 1695 1590
1750 1670 1570
1725 1645 1545
1700 1620 1520
1325
1310
1290
1275
1260

All outputs to the nearest 5 W/m2.
Panel emissions are based upon turbulent water flowing through tubes.

Floor Panel emissions are based on stainless steel face plates with a coarse grain matt polish, the emissivity factor being taken as 0.5

Ceiling and Wall Panel emissions are based upon surfaces with an emissivity factor of 0.85. However, various published data indicates that the emissivity of a painted surface is 0.9 - 0.95 and therefore, after due consideration of the surface, the total emissions may be increased by 3 - 6%